All bid deadlines are 11:59pm Pacific Time the date of the bid deadline listed unless otherwise noted.

school Bixby ISD 4
IFCB Posted : Nov 7, 2024
Bid Deadline : Saturday, Dec 21, 2024

Questions Due By : Saturday, Nov 23, 2024
Applicant Address : Bixby, OK 74008
IFCB ID : 250004769

IFCB Requirements :

·       Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).

·      For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.

 

·       Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·       Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·       By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·       Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·       Contracts must not prohibit SPIN changes.

 

·       Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·       Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·       All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·       All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·       If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

·       LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

·       LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

·       LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS – PROJECT A & B: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

·       DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B, Project C and/or Project D.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

·       DISQUALIFICATION FACTOR BMIC: Service providers are required to bid an entire Project E and/or Project F.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

·       DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·       DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

·       DISQUALIFICATION FACTOR MIBS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·       DISQUALIFICATION FACTOR MIBS: Service providers are required to bid the entire Project G.  Bids for individual components, or bids that do not include all of the requested items for the project of the project will be disqualified.


Services and Equipment Requested :

Category One:

Leased Lit Fiber – 10 GB bandwidth from 501 S Riverview, Bixby OK 74008 to 14901 S Harvard Ave, Bixby OK 74008. Bids should be based on 5-year pricing.

 

NOTE: Applicant will accept any technologies bid. It is our intention to meet all OUSF Fair and Open Competitive Bidding requirements. If you are a NECA/tariffed company, bids for your tariffed rates are allowed. If any of the specified bandwidth speeds are not a tariffed/NECA rate, please bid the closest rate you have available, within the limits of the bandwidth range specified on the 470.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bidders who are not eligible to provide OUSF support will be disqualified. By placing a bid for these services, the bidder agrees to file the completed OUSF affidavit within 90 days of the start of service (applicant agrees to complete their portion in a timely fashion after the request for completion by the winning bidder).

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Bids submitted for services to an incorrect address will be disqualified.

 

LEASED LIT FIBER DISQUALIFICATION FACTOR: Any and all installation charges must be identified on your bid. If you submit a bid indicating that installation charges may apply without listing those charges, we will consider your bid incomplete and disqualify your bid.

 

Category Two:

VOLUNTARY SITE VISIT

Vendors wishing to bid on C2 can attend a voluntary site visit either November 21, 2024 or November 22, 2024. Vendors should RSVP to Amy Reneau at areneau@bixbyps.org to set up a time for a site visit on November 21, 2024 or November 22, 2024. THIS EMAIL IS TO RSVP ONLY. ALL QUESTIONS AND BIDS MUST STILL BE SUBMITTED VIA THE IFCB. BIDS NOT SUBMITTED VIA THE IFCB WILL BE DISQUALIFIED.

 

INTERNAL CONNECTIONS

IC Project A – Equipment 1 YR.

No cabling drops needed. Installation of WAPs and installation & configuration of switches needed.

Note: The district will move forward with Project A or Project B – not both.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

90

Modules/GBIC compatible with switches

Switches

90

Aruba PoE+ 48 Port, 10 GB SFP+ with 1 year licensing

UPS/Battery Backup

45

No preference - 2U RMS, 1500VA, 1050W with 8 Outlets, Rackmount with minimum 7 minutes run time

Wireless Access Points

300

Aruba – indoor, WiFi 6 with 1 year licensing

 

NOTE: We are requesting WAP and/or switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

WAPs must compatible with existing Aruba 7220 mobility controller

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS – PROJECT A & B: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

IC Project B – Equipment 3 YR.

No cabling drops needed. Installation of WAPs and installation & configuration of switches needed.

Note: The district will move forward with Project A or Project B – not both.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Antennas, Connectors and Related Components

90

Modules/GBIC compatible with switches

Switches

90

Aruba PoE+ 48 Port, 10 GB SFP+ with 3 year licensing

UPS/Battery Backup

45

No preference - 2U RMS, 1500VA, 1050W with 8 Outlets, Rackmount with minimum 7 minutes run time

Wireless Access Points

300

Aruba – indoor, WiFi 6 with 3 year licensing

 

NOTE: We are requesting WAP and/or switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

WAPs must compatible with existing Aruba 7220 mobility controller

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS – PROJECT A & B: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

IC Project C – Licensing 1 YR

Licensing for existing switches and WAPs.

Note: The district will move forward with Project C or Project D – not both.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Switch Licensing

40

Aruba 6200 – 1 yr Aruba Central

Wireless Access Points Licensing

600

Aruba 635 – 1 yr Aruba Central

 

NOTE: We are requesting WAP and/or switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

IC Project D – Licensing 3 YR

Licensing for existing switches and WAPs.

Note: The district will move forward with Project C or Project D – not both.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Switch Licensing

40

Aruba 6200 – 3 yr Aruba Central

Wireless Access Points Licensing

600

Aruba 635 – 3 yr Aruba Central

 

NOTE: We are requesting WAP and/or switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS – PROJECT A & B: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A, Project B, Project C and/or Project D.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

BASIC MAINTENANCE OF INTERNAL CONNECTIONS:

BMIC Project E – New Equipment

The district would like a block of 40 hours per month for the support of eligible equipment.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Switches

90

Aruba PoE+ 48 Port, 10 GB SFP+

Wireless Access Points

300

Aruba – indoor, WiFi 6

 

BMIC Project F – Existing Equipment

The district would like a block of 40 hours per month for the support of eligible equipment.

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service and Components

1

Fortinet Firewall 600E

Switches

2

Aruba 5412

Switches

12

Aruba 2530

Switches

68

Aruba 2540

Switches

1

Aruba 2610

Switches

7

Aruba 2910

Switches

10

Aruba 2920

Switches

2

Aruba 3500

Switches

40

Aruba 6200

Wireless Access Points

600

Aruba 635

Wireless Controller

1

Aruba 7220

 

DISQUALIFICATION FACTOR BMIC: Service providers are required to bid an entire Project E and/or Project F.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

DISQUALIFICATION FACTOR BMIC: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR BMIC: Maintenance bids listing only an hourly rate and not a monthly or annual total will be disqualified.  Vendors quoting an hourly rate are required to also a) confirm that you have the ability/expertise to maintain all of the equipment listed and b) propose a number of hours at a particular rate monthly to properly maintain the entire list of equipment.  Bids that contain only hourly rates, without confirmation that the company can service the list of equipment, or without a monthly total will be disqualified.

 

Managed Internal Broadband Service (MIBS):

MIBS Project G – Existing Equipment

The district would like MIBS services for the following existing equipment:

 

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service and Components

1

Fortinet Firewall 600E

Switches

2

Aruba 5412

Switches

12

Aruba 2530

Switches

68

Aruba 2540

Switches

1

Aruba 2610

Switches

7

Aruba 2910

Switches

10

Aruba 2920

Switches

2

Aruba 3500

Switches

40

Aruba 6200

Wireless Access Points

600

Aruba 635

Wireless Controller

1

Aruba 7220

 

DISQUALIFICATION FACTOR MIBS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR MIBS: Service providers are required to bid the entire Project G.  Bids for individual components, or bids that do not include all of the requested items for the project of the project will be disqualified.

 


There is an additional document associated with this IFCB. Please click the buttons to download the document.

2025_C2_Bidding_Instructions108.pdf
BIXBY_C2_COVER_PAGE.pdf

You need to login / register to upload bid.

Questions Received with Applicant Answers   ( Ask Questions? )




Hi, Could you please find the serial number for the Fortinet FG-600E? It is required for determine the price quote. Thanks,

Answer:

FG6H0ETB20903295 

For the SFP+ are they wanting LR or SR ? What nm on the fiber 850 1310 ?

Answer:

SFP+ is SR

Fiber: Current fiber patch cables are: Commscope FFXLCLC42-MXF007

In regards to "Modules/GBIC compatible with switches" in Project A and B, what speed (10G, 25G, 40G) and fiber mode (Single Mode, Multi Mode) are you needing modules to support?

Answer:

Speed: 10G

Fiber: Multimode

You need to login / register to post question.