school South Rock Creek School District
IFCB Posted : Nov 19, 2024
Bid Deadline : Tuesday, Dec 31, 2024

Questions Due By : Thursday, Nov 28, 2024
Applicant Address : Shawnee, OK 74801
IFCB ID : 250006251

IFCB Requirements :

·         Before the listed deadlines, all Questions and Bids must be submitted using the on-line IFCB system. Bids submitted before the bid deadline outside of this system will be disqualified. If the system is down before the deadline, please email your bid to info@crwconsulting.com or fax it to 918.445.0049. Bids or questions submitted in this fashion will be disqualified if the on-line system is active at the time of submission. The applicant reserves the right to request and obtain bids outside of the website system if the bid deadline has passed and zero or one bid is received (the intent for this is to follow USAC guidance on obtaining cost-effective bids).

·        For all requested services and/or products listed on this IFCB: proposals that include generic/encyclopedic price lists will be considered non-responsive and will be disqualified. SPAM and/or robotic responses will not be considered valid bid responses and will be disqualified from consideration.

 

·         Bidder must agree to participate in USF Program (AKA “E-rate”) for the corresponding funding year.

 

·         Please include the correct Service Provider Identification Number (SPIN) on your bid.

 

·         By submitting a bid, bidder certifies that the bidder does have a valid (non-red light status) SPIN for the E-rate program at the time of submission. Should the Applicant discover that the bidder is on red light status, or if the FCC classifies the bidder as on red-light status before work is performed and invoices are paid, the contract will be null and void and the applicant will have no payment obligations to the bidder.

 

·         Bidder is expected to provide the lowest corresponding price per E-rate rules.  See https://www.usac.org/e-rate/service-providers/step-2-responding-to-bids/lowest-corresponding-price/ for details.

 

·         Contracts must not prohibit SPIN changes.

 

·         Bidder must agree to provide the Applicant the choice of discount methods (SPI or BEAR).

 

·         Bidder will be automatically disqualified if the District determines that the bidding company has offered any employee of the District any individual gift of more than $20 or gifts totaling more than $50 within a 12 month period. This does not apply to the recent FCC exemptions of the Gift Rule for the COVID pandemic.

 

·         All contracts awarded will be contingent upon E-rate funding and final board approval.  The applicant may choose to do all or part of the project upon funding notification.

 

·         All applicable fees, surcharges, and taxes must be identified on the bid. E-rate rules require the applicants to evaluate the price of eligible goods and services that will be listed on the 471 application during the competitive bidding process. Fees and surcharges that apply but are not listed on the bid will be the responsibility of the bidding company, should their bid be awarded.

 

·         If there is a request for Internal Connections (Category Two) equipment, or Category One equipment listed on this IFCB the applicant will accept bids for functionally equivalent equipment.

 

·         HOT SPOTS & SERVICE FOR HOME INTERNET USE DISQUALIFICATION FACTOR:  Service providers are required to bid both services and equipment.  Bids received for only services or only equipment will be disqualified as incomplete.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

 

·         DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A or Project B.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 


Services and Equipment Requested :

NOTE: IF YOU PREVIOUSLY SUBMITTED A BID UNDER 470/IFCB #250005935 YOU MUST SUBMIT A NEW BID UNDER 470/IFCB# 250006251. CABLING HAS BEEN REMOVED FROM IC PROJECT B.

 

Category One:

 

Hot Spots & Service for Home Internet Use - The district is requesting bids for 10 hot spot devices including 10 monthly service plans.  The district is requesting service plans with a minimum 3Mb bandwidth and maximum 20Gb bandwidth.  Please include any installation, activation, configuration costs in your pricing.  Please include separate pricing for any CIPA/filtering costs. 

 

HOT SPOTS & SERVICE FOR HOME INTERNET USE DISQUALIFICATION FACTOR:  Service providers are required to bid both services and equipment.  Bids received for only services or only equipment will be disqualified as incomplete.

 

Category Two:

INTERNAL CONNECTIONS

IC Project A – Firewall

No installation needed.

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Firewall Service and Components

1

Ubiquiti

 

NOTE: We are requesting firewall licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

All equipment must be compatible with existing Ubiquiti network.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

 

INTERNAL CONNECTIONS

IC Project B – Network Equipment

No installation or drops needed.

Type of Equipment

Quantity Vendor Should Bid

 

Preferred Make/Manufacturer

Caching Server

1

Dell

Racks

2

No preference - Full rack

Racks

1

No preference - ½ rack

Router

1

Ubiquiti

Switches

12

Ubiquiti 48 port

Modules, GBIC, transceivers

4

No preference - GBIC

Modules, GBIC, transceivers

6

No preference SPF

UPS/Battery Backup

6

APC 120v 1500mv

Wireless Access Points

16

Ubiquiti  2 Pro

Wireless Controller

1

Ubiquiti

 

NOTE: We are requesting WAP and/or wireless controller and/or switch licenses on this IFCB, which sometimes may be categorized as BMIC or MIBS by USAC (the BMIC and MIBS boxes on the 470 have been checked to cover this scenario).

 

COMPATIBILITY REQUIREMENT:

All equipment must be compatible with existing Ubiquiti network.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: The applicant will not accept bids from manufacturers of equipment deemed a national security threat by the Federal Communications Commission. The list of prohibited equipment is available here: https://www.fcc.gov/supplychain/coveredlist . Vendors that submit bids that includes these manufacturers will have their bid disqualified.

 

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Vendors must complete and include the C2 Cover Page with their bid. Bids received without the cover page will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: It will be the bidder’s responsibility to provide documentation about the compatibility requirements listed in this IFCB. Vendors that submit bids without documentation demonstrating the required compatibility listed in this IFCB will have their bids disqualified, unless that vendor has bid the preferred make/model number listed.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Applicant will not accept bids for refurbished equipment. Any bids containing refurbished equipment will be disqualified.

DISQUALIFICATION FACTOR INTERNAL CONNECTIONS: Service providers are required to bid an entire Project A or Project B.  Bids for individual components, or bids that do not include all of the requested items for the project will be disqualified.

 

 


There is an additional document associated with this IFCB. Please click the buttons to download the document.

2025_C2_Bidding_Instructions135.pdf
SOUTH_ROCK_CREEK_C2_COVER_PAGE1.pdf

Questions Received with Applicant Answers   ( Ask Questions? )




QUESTIONS FOR E-RATE 470/RFP UPS: --Are the UPS units rack mount or tower? --Are the UPS units going into floor mount enclosed cabinets? -- Are the UPS units going into floor mount 2-post or 4-post open frame racks? -- Are the UPS units going into wall mount enclosed cabinets? If so, what size of cabinet? -- Are the UPS units going into wall mount open frame racks? If so, what size of rack? --Will current racks/cabinets accommodate new UPS units? --Do you need a network card in each UPS? WIRELESS ACCESS POINTS: --What is the current wireless access point network? Make and model --Are you adding to an existing wireless access point network or replacing all existing? --Are there any high-density areas such as Gym, Café or Library that would require a more-robust wireless access point? --If high density is needed, how many locations? --Is a scissor lift required to install any AP’s? MODULES/TRANSCEIVERS: --Do you need 1G multi-mode or single-mode transceivers? RFP – Qty 4 GBIC --Do you need 10G multi-mode or single-mode transceivers? RFP – Qty 6 SFP RACK/CABINET: --What is the district definition of “full rack”? RFP – Qty 2 --What is the district definition of “half rack”? RFP – Qty 1 --Do you need floor mount or wall mount open-frame racks. --Do you need floor mount or wall mount enclosed cabinets. --Are the requested rack/cabinets replacing an existing rack/cabinet? --If so, is there enough slack in the existing network cabling going to the patch panels to be able to remove existing patch panels without compromising the existing cabling connections? --If replacing, can you provide picture(s) of rack/cabinet?

Answer:

Mount

Full racks on rollers and closed, back can be open

Yes network card

Ubiquiti, adding and replacing

2 locations for high density

No scissor lift

1G SM

For the GBIC modules what kind of device are they going to be used in? Do they need to support SM, MM, or Copper connectivity? Do the GBIC's need to be 1G or 10G capable? For the SFP modules what kind of device are they going to be used in? Do they need to support SM, MM, or Copper connectivity? Do the SFP's need to be 1G or 10G capable? For the Firewall what speeds need to be supported on LAN/WAN? How many U's are you looking for on your 1/2 and Full Racks? Do you want the UPS to be rack mounted or free standing?

Answer:

Used in fiber connections.

Support SM

GBIC's Minimum of 1G

SFP is currently in a Trendnet device.

SFP Minimum of 1G

Firewalls minimum of 1G

SFP SM

U's- Full-46, Half-20

Rack mounted